AT Command Set Reference
Ver. 1.00
GSM1308AT001 Page 261 Ver. 1.00 – 10/29/2008
4.8. PAD Commands
4.8.1. $PADDST PAD Destination IP/Port
Command Function This command allows the user to query/set
the PAD destination IP and port address.
Command Functional Enfora Specific
Group
Command Format Query AT$PADDST=?
Response $PADDST: "(0-255),(0-255),(0-255),(0-
255)",(0-65535)
OK
Write Format AT$PADDST =”<PAD destination
Response IP> or <PAD destination DNS
name>”,<PAD destination port>
OK
Read Format AT$PADDST?
Response $PADDST: =”<PAD destination IP> or
<PAD destination DNS name>”,<PAD
destination port>
Execution Format N/A
Response N/A
Parameter Values
<PAD destination IP > Destination IP for PAD data. PAD data is
sent to and received from this IP. A
destination IP address of 0 will allow PAD
access from any IP destination, and will
cause all locally generated PAD data to be
sent to the IP address associated with the
last remotely received PAD data.
OR
<PAD destination DNS name> Destination DNS name for PAD data.